Features:
- Output Power Factor: 1.0
- Wi-Fi & GPRS available for iOS and Android
- One-Key Restoration to Factory Settings
- Built-in Lithium Battery with Automatic Activation
- Integrated Design
- Built-in 120A MPPT Solar Charge Controller:
- Maximum Output: 6200W (for 4.2KW system)
- Maximum Output: 6500W (for 6.2KW system)
- High PV Input Voltage Range: 60-500 VDC
- Built-in Anti-Dust Kit for Harsh Environments
- Smart Battery Charge Design to Optimize Battery Life
- Dual Output Ports
Product Data Sheet
MODEL | VICTOR NM-ESSM-4.2KW PLUS-100AH/200AH | VICTOR NM-ESSM-6.2KW PLUS-100AH | ||
Phase | ||||
Maximum PV Input Power | 6200W | 6500W | ||
Rated Output Power | 4200W/4200VA | 6200W/6200VA | ||
Maximum Solar Charging Current | 120A | |||
GRID-TIE OPERATION | ||||
PV INPUT(DC) | ||||
Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | |||
Start-up Voltage/Initial Feeding Voltage | 60VDC/90VDC | |||
MPPT Voltage Range | 60~450VDC | |||
Maximum Input Current | 1/18A | 1/22A | ||
GRID OUTPUT(AC) | ||||
Nominal Output Voltage | 220/230/240VAC | |||
Output Voltage Range | 195.5~253VAC | |||
Nominal Output Current | 18.2A | 27.0A | ||
Power Factor | >0.99 | |||
EFFICIENCY | ||||
Maximum Conversion Efficiency(DC/AC) | 98% | |||
TWOLOAD OUTPUT POWER | ||||
Full Load | 4200W | 6200W | ||
Maxium Main Load | 4200W | 6200W | ||
Maxium Second Load(battery mode) | 1400W | 2067W | ||
Maxium Load Cut Off Voltage | 26VDC | 52VDC | ||
Maxium Load Return Voltage | 27VDC | 54VDC | ||
OFF-GRID OPERATION | ||||
AC INPUT | ||||
AC Start-up Voltage/Auto Restart Voltage | 120-140VAC/180VAC | |||
Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | |||
Frequency Range | 49~51±1HZ | |||
MaximumAC Input Current | 24.7A | 36.4A | ||
PVINPUT(DC) | ||||
Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | |||
MPPT Voltage Range | 60~450VDC | |||
Maximum Input Current | 1/18A | 1/22A | ||
BATTERY MODE OUTPUT(AC) | ||||
Nominal Output Voltage | 220/230/240VAC | |||
Output Waveform | Pure sine wave | |||
Eficiency(DC to AC) | 94% | |||
BATTERY&CHARGER | ||||
Nominal DC Voltage | 24VDC | 48VDC | ||
Maximum Solar Charging Current | 120A | 140A | 120A | |
Maximum AC Charging Current | 100A | 100A | 100A | |
Maximum Solar+AC Charging Current | 120A | 140A | 120A | |
HYBRID OPERATION | ||||
PV INPUT(DC) | ||||
Nominal DC Voltage/Maximum DC Voltage | 360/500VDC | |||
Start-up Voltage/Initial Feeding Voltage | 90VDC/120VDC | |||
MPPT Voltage Range | 60~450VDC | |||
Maximum Input Current | 1/18A | 1/22A | ||
GRID OUTPUT(AC) | ||||
Nominal Output Voltage | 220/230/240VAC | |||
Output Voltage Range | 195.5~253VAC | |||
Nominal Output Current | 18.2A | 27.0A | ||
AC INPUT | ||||
AC Start-up Voltage/Auto Restart Voltage | 120-140VAC/180VAC | |||
Acceptable Input Voltage Range | 90-280VACor 170-280VAC | |||
Maximum AC Input Current | 24.7A | 36.4A | ||
MaximumAC Charging Current | 100A |
|