VICTOR MAX SERIES

VICTOR MAX SERIES

8.2KW/10.2KW

RFQ
Request For Quote
Name
*
Whatsapp:
*
Email
*
Country or Region
*
Comments
*
Verification code
 Change Image
*
Submit

Features:

- Output power factor: 1.0

- WFi & GPRS available for iOS and Android

- Can operate without a battery

- High PV input voltage range: 90-500 VDC

- Built-in anti-dust kit for harsh environments

- Smart battery charging design to optimize battery life

- Dual output

- One-key restoration to factory settings

- Dual PV input

- Built-in lithium battery automatic activation

- Touch button interface

- Built-in 160A MPPT solar charger (for 8.2 kW and 10.2 kW models)

- Supports both On and Off Grid operating modes

- Dual communication ports for battery and WiFi communication





Product Data Sheet


MODELVICTOR MAX-8.2KWVICTOR MAX-10.2KW
Phase
1-phase
Maximum PVInput Power
5400W+5400W
Rated Output Power8200W/8200VA10200W/10200VA
Maximum Solar Charging Current
160A
Nominal DC Voltage/Maximum DC Voltage360/500VDC
Start-up Voltage/Initial Feeding Voltage90VDC/120VDC
MPPTVoltage Range90~450VDC
Maximum Input Current2/18A
GRID OUTPUT(AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range195~253VAC
Nominal Output Current35.6A44.3A
Power Factor>0.99
EFFICIENCY
Maximum Conversion Eficiency(DC/AC)98%
TWO LOAD OUTPUT POWER
FullLoad8200W10200W
Maxium Main Load8200W10200W
Maxium Second Load(battery mode)2733W3400W
Maxium Load Cut Off Voltage52VDC
Maxium Load Return Voltage54VDC
OFF-GRID       OPERATION
AC INPUT
AC Start-up Voltage/Auto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VACor170-280VAC
Frequency Range59~61±1HZ
MaximumAC Input Current48.2A60A
PVINPUT(DC)
Nominal DC Voltage/Maximum DC Voltage360/500VDC
MPPT Voltage Range90~450VDC
Maximum Input Current2/18A
BATTERY MODE OUTPUT(AC)
Nominal Output Voltage220/230/240VAC
Output WaveformPure sine wave
Efficiency(DC toAC)94%
BATTERY&CHARGER
Nominal DC Voltage48VDC
Maximum Solar Charging Current160A
MaximumAC Charging Current140A
Maximum Solar+AC Charging Current160A
HYBRID       OPERATION
PV INPUT(DC)
Nominal DC Voltage/Maximum DC Voltage360/500VDC
Start-up Voltage/Initial Feeding Voltage90VDC/120VDC
MPPT Voltage Range90~450VDC
Maximum Input Current2/18A
GRID OUTPUT(AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range195~253VAC
Nominal Output Current35.6A44.3A
AC INPUT
AC Start-up Voltage/Auto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VAC or 170-280VAC
MaximumAC Input Current48.2A60A
MaximumAC Charging Current140A
GENERAL PHYSICAL
Dimension,D*W*H(mm)530*390*130
Cartoon Dimension,D*W*H(mm)618*463*205
Net Weight(kgs)14.214.7
Gross Weight(kgs)15.716.2
INTERACE
Communication PortRS232/RS485/WIFI/GPRS/LITHIUM BATTERY
ENVIRONMENT
Humidity5%to 95%Relative Humidity(Non~condensing)
Operating Temperature-10℃~50℃
STANDARD
Compliance SafetyCE